EAPL Motor Protection Relay MPR-E1
Brand : EAPL
Model : MPR-E1
Features :
Micro controller based motor protection relay, Bypass of unwanted parameter can be programmed.
Trip delay time programmable for each parameter separately, Program lock facility available
Relay can be programmed for relay to get energized during healthy or unhealthy condition.
Instant values of parameter displayed during healthy status. Reason for tripping displayed during unhealthy status.
Auto / Manual mode available, Panel / Flush mounting
Parameters: Phase- Phase missing (failure), phase reversal (sequence) and phase unbalance, Voltage – under voltage, over voltage based on 415V AC, Current – Under current, Over current based on nominal current set, Frequency – Under frequency, Over freque
CT primary can be programmed up to 2500 in steps of 5. CT secondary will be factory set for 5.
Function :
Monitoring and controlling of phase missing, negative phase sequence, phase unbalance, under voltage, over voltage, under current, over current, under frequency, over frequency and earth current leakages
Specifications :
Rated Supply Voltage : 440V AC, 3 phase, 3 wire
Control Relay Output : 1c/o rated for 5A@250V AC /28V DC resistive load
Recovery Time : 100msec minimum
Mode of Operation : Manual / Auto
For more information, please visit our website :www.autocon.biz
Model : MPR-E1
Features :
Micro controller based motor protection relay, Bypass of unwanted parameter can be programmed.
Trip delay time programmable for each parameter separately, Program lock facility available
Relay can be programmed for relay to get energized during healthy or unhealthy condition.
Instant values of parameter displayed during healthy status. Reason for tripping displayed during unhealthy status.
Auto / Manual mode available, Panel / Flush mounting
Parameters: Phase- Phase missing (failure), phase reversal (sequence) and phase unbalance, Voltage – under voltage, over voltage based on 415V AC, Current – Under current, Over current based on nominal current set, Frequency – Under frequency, Over freque
CT primary can be programmed up to 2500 in steps of 5. CT secondary will be factory set for 5.
Function :
Monitoring and controlling of phase missing, negative phase sequence, phase unbalance, under voltage, over voltage, under current, over current, under frequency, over frequency and earth current leakages
Specifications :
Rated Supply Voltage : 440V AC, 3 phase, 3 wire
Control Relay Output : 1c/o rated for 5A@250V AC /28V DC resistive load
Recovery Time : 100msec minimum
Mode of Operation : Manual / Auto
For more information, please visit our website :www.autocon.biz